Please see the appropriate design information in the research notes under the research heading.
Prestressed roof plank design example.
A c 135 2103 mm2 i 678 106 mm4 y t 99 mm f ck.
Geometric and data given by the manufacturer are as follows.
The plank is manufactured on 500 foot long beds in a standard width of 48 inches and thicknesses of 8 10 and 12 inches.
The example in section 10 2 provides design parameters used in this example.
3 6 a floor system alternate 1 prestressed plank and half slab floor system this precast floor system refer to figure 3 12 comprises prestressed planks spanning between load bearing walls.
Plank is cut to length for each project.
Prestressed solid composite planks.
8 1 1 1 general design requirements.
Load balancing is used a portion of the load on slab is balanced by the transverse forces imposed by the draped tendons in each direction.
Design steel plank support headers at openings when headers are determined necessary by the manufacturer s engineer.
The floors and roofs of these buildings are to be untopped 8 inch thick hollow core precast prestressed concrete plank.
Instructional material complementing fema 752 design examples precast concrete 5.
Some of the images and calculations included in this article were taken from the worked example of prestressed concrete girders according to eurocode 2 published by the fachvereinigung deutscher betonfertigteilbau e.
General after making an initial selection of the slab thickness the second step in slab design is to determine the amount and distribution of prestress.
The example in section 8 4 shows a partial example for the design of a special moment frame constructed using precast concrete per aci 318 section 21 8.
Where voids stairs and other features prevent the slabs from spanning between walls slabs spanning perpendicularly are provided supported by the.
Take the final long term losses as 24.
High strength prestressing strands are cast into the plank at the spacing and.
For double tees such distribution of loads is a special design consideration and our engineering department should be consulted for more information.
This article deals with the design of prestressed precast elements with pretensioned tendons according to ec2.
Figure 10 2 1 shows the typical floor plan of the diaphragms.
Example 1 calculate m sr for the 203 mm deep prestressed hcu shown below.
In spancrete hollowcore plank such loads may be distributed over several slabs.
The design is in accordance with as 3600.
Prestressed solid composite planks comprises a wet cast prestressed concrete element combined with insitu concrete structural topping to give an overall solid composite slab.